POLY-PROPELENE VERTICAL GLANDLESS PUMP
INSTALLATION GUIDE

Tank overflow 'D' is to prevent liquid level rising in pump body and damaging the motor. The lower lip of overflows 'D' should not to move than 1/2" above center of pump overflow. Isolation valve for scaling the tank during maintenance not essential for efficient working of the pump.

A vertical suction pipe with non-return valve with entering top of tank may be used when liquid is free from suspended solids


INSTALLATION 1

  1. Fully open valve 'A'
  2. Allow level of liquid to rise in supply tank up to overflow 'D' level
  3. Close valve 'B'
  4. Start pump
  5. Open valve 'B' gradually for required flow


INSTALLATION 2

  1. Close valves 'A' and 'B'
  2. Open valve 'D' and leave running until liquid flows out of 'C'
  3. Start pump and immediately open valve 'A' fully
  4. Close valve 'D'
  5. Open valve 'B' gradually for required flow.
Valve 'A' must be at least 1/2 size large in bore then suction pipe

INSTALLATION 3

  1. Close valves 'A' and 'B'
  2. Open valve 'D'
  3. Fill priming vessel to overflow 'C'
  4. Start pump
  5. Open valves 'A'
  6. Close valve 'D' and open valve 'B' for flow required

INSTALLATION 4

  1. Close valve 'A' and 'B'
  2. Fill priming vessel
  3. Start pump
  4. Open valve 'A' gradually until fully open
  5. Open valve 'B' gradually for required flow

INSTALLATION & OPERATION

  1. Where Low Level priming is not required

  2. Where Low Level priming is required.

  3. Where priming at all levels is required.

  4. Where priming at all levels is required without re-circulation.

  5. For deep variable head storage tanks or where suction lifts must be hopt to minimum.

All installation must have the overflow from the pump to the supply or priming vessel:-

  • Straight
  • Have no restriction (valves etc.)
  • Stop down -1 in 20 or more
  • Preferably 12" long maximum
  • Valves 'A' to be of the free flow type.

INSTALLATION 5

This installation is basically scheme 1 but level in supply tank is regulated by a mechanical or electrical flow control valve.
Installation for deep variable head storage tanks, or where suction lifts must be kept to a minimum.


E-mail

Products Range

 
Site Developed By Vinayak InfoSoft
BHAGWATI ENGINEERING WORKS
Manufacturer & exporter - submergd vertical pump,poly-propelene vertical glandless pump
#1 Ahmedabad Web Designing | #1 Ahmedabad Web Hosting. | #1 Outsourcing Web Designing | #1 Outsourcing Web Promotion | #1 Web Designing Web Promotion | #1 Cheap Outsourcing India | Ahmedabad Industrial Directory | Mumbai Web Designing | Zed Plus Software Force | New Cloth Market
Indian Textile | Indian Textile.co.in | Indian Garment | www.indiangarment.co.in | Textile Agent | Maheshwaries | www.maheshwaries.co.in | Maheshwari | Industrial Valves | www.IndustrialValves.co.in | Pharma Machines | Packaging Machine | www.PackagingMachine.co.in | Machine Manufacturer | www.MachineManufacturer.co.in | Indian Model

Home Page Company Profile Company Products Enquiry.htm Contact Address